Software Upgrade For Pild; Procedure For Upgrading The Software From Hart Host Application - Honeywell ST 800 Series User Manual

Pressure transmitter
Hide thumbs Also See for ST 800 Series:
Table of Contents

Advertisement

9.4

Software Upgrade for PILD

This procedure enables the PILD option in an ST 800 device that was not ordered from the factory.
This requires the user to obtain and install a License Key. This procedure can be performed from both
host application and integral display of the device to activate this option.

Procedure for upgrading the software from HART host application

Retrieve the Dev Id parameter shown on the Device Setup->Upgrade Options menu.
Reference document PILD Upgrade Option, ST 800 Instruction Sheet (34-ST-33-73) for
firmware revision level requirements.
Verify firmware revisions in device meet the following required minimum revision levels for
PILD Option Licensing support:
-
Basic Display: 1.08
-
Advanced Display (Euro): 1.12
-
Advanced Display (Asia): 1.13
-
HART Comm Firmware: 1.10
-
Sensor Firmware: 1.03
Please reference your User Manual on how to obtain firmware revision numbers from a
device. If you need technical support contact Honeywell GTS at 1-800-423-9883.
Place an order for the ST 800 PILD Field Upgrade kit, part number 50097038-501. Include
the following information with the order:
-
The Dev Id of the device
-
Feature requires license: PILD Field upgrade for ST 800 (Part Number - 50097038-
501)
The factory or Honeywell factory] generates and sends a License Key to customer.
The customer installs the license by selecting the "Enter License Key" method on the Device
Setup->Upgrade Options menu.
On confirmation of the license activation,
-
The transmitter's integral display, if present, will restart.
-
The PILD Functionality parameter on the Device Setup->Upgrade Options menu will
show the value "Available"
Revision 5.0