Replacing 24V External Power Module; When To Replace; Tools Required; Procedure - Honeywell XYR 6000 User Manual

Onewireless hlai transmitter
Hide thumbs Also See for XYR 6000:
Table of Contents

Advertisement

6.4

Replacing 24V external power module

When to replace

When the transmitter displays LOW PWR and external power is present and sufficient. When the external
power is removed to allow replacement of the module, all transmitter data is retained in the transmitter's
nonvolatile memory.

Tools required

#1 Phillips Screwdriver or 1/8" Slotted Screwdriver
Torque Screwdriver
1.5 mm hex key

Procedure

ATTENTION
24V power module must be replaced only by a trained service technician.
WARNINGS
Risk of death or serious injury by explosion. Do not open transmitter
enclosure when an explosive gas atmosphere is present.
SHOCK HAZARD
Depending on your installation, transmitter input wiring sources may contain
high voltage. Disconnect all power from transmitter input sources before
accessing the 24V power module. Failure to do so could result in death or
serious injury if the input terminals or wires are accidentally touched.
Revision 9
July 2011
OneWireless XYR 6000 HLAI Transmitter R120 User's Manual
6. Maintenance/Repair
6.4. Replacing 24V external power module
35

Advertisement

Table of Contents
loading

This manual is also suitable for:

Onewireless xyr 6000