Honeywell XYR 6000 User Manual page 32

Onewireless hlai transmitter
Hide thumbs Also See for XYR 6000:
Table of Contents

Advertisement

5. Operation
5.3. Transmitter PV display
Transmitter
Wireless Builder display
display
NO RADIO
Radio Interprocessor
Comm Error
BAD RADIO
Sensor Radio SPI
SPI
Communication Failure
BAD RADIO
EEPROM SPI
EEPROM
Communication Failure
RADIO WDT
WDT Reset Occurred
RESET
BAD RADIO
Radio Circuitry Failure
The following status messages have multiple meanings. Refer to Wireless Builder Device Status for exact cause.
E FAIL
A/D Failure
E FAIL
Electronics Failure
E FAIL*
NVM Fault*
E FAIL*
Program Memory Fault*
E FAIL*
RAM Fault*
INP FAIL
Input Failure
20
Definition
Radio Board is not
accessible.
Radio detected loss of
communication with
sensor board over the
inter-processor
communication link.
Radio EEPROM SPI
Communication failure
Radio Watch Dog
Timeout detected
Radio circuitry has failed
Diagnostics detected
defect with Analog to
Digital Converter.
Electronic Failure
detected on Sensor
Board. Could be caused
by one of the status
items marked by *.
Startup diagnostics
detected defect in
Sensor Non-Volatile
Memory
Startup diagnostics
detected defect in
Sensor Read Only
Memory
Startup diagnostics
detected defect in
Processor Random
Access Memory
Input Error
OneWireless XYR 6000 HLAI Transmitter R120 User's Manual
What to do
Restart both the radio and sensor.
If condition persists, replace
sensor module. See page 30.
Restart both the radio and sensor.
If condition persists, replace
sensor module. See page 30.
The radio will not be able to
perform firmware upgrades but will
operate normally using installed
code. Replace sensor module.
See page 30.
Restart both the radio and sensor.
If condition persists, replace
sensor module. See page 30.
The radio processor detected error
on internal radio circuitry. Replace
sensor module. See page 30.
Replace sensor module. See page
30.
Restart both the radio and sensor.
If condition persists, replace
sensor module. See page 30.
Replace sensor module. See page
30.
Replace sensor module. See page
30.
Replace sensor module. See page
30.
Check input connection.
Check input configuration.
Restart the sensor. If condition
persists, replace sensor module.
See page 30.
Revision 9