Download Print this page

Honeywell DR4200 Replacement Instructions page 3

Chart motor kit (30756113-501)

Advertisement

Component Location
for DR4500
DR4500 Procedure
Form 44-45-33-37B
Refer to Figure 2 for the component locations and Table 2 for the
installation procedure.
Figure 2 – Component Location
Follow the procedure in Table 2 to replace the existing chart motor
assembly in your recorder.
Table 2 – Chart Motor Assembly Replacement for DR4500 Recorder
Step
1
Open the chart door and swing the chart plate out.
2
Remove chart hub and motor assembly by removing screws
and cutting tie wraps. Discard hub and motor, but save
screws.
3
Use new tie wraps to re-secure wires.
4
Refer to Chart Hub replacement instructions (steps 3-6) for
remaining steps.
24241
Chart Motor
Action
Kit Instruction, continued
Chart
Hub
Spring
Page 3 of 3