Replacing The Fan Assembly - Cisco 10005 ESR Manual

Table of Contents

Advertisement

Chapter 3
Maintaining the Cisco 10005 ESR
Step 5
Step 6

Replacing the Fan Assembly

Caution
Step 1
Step 2
Warning
OL-1102-07
To replace the filter cover, insert the tab on the bottom of the cover into the slot at
the bottom of the air filter compartment. Pivot the cover up into place.
Turn the cam fastener ½ of a rotation (180 degrees) to secure the filter to the
chassis.
The fan assembly supports hot-swapping (for up to 2 minutes) and can be replaced
without interruption to system operation.
The fan assembly is accessible from the rear of the chassis. It occupies a vertical
slot on the right side of the unit.
To prevent the system from overheating, be sure that the replacement fan
assembly is out of its box and packaging, so it is ready to install as soon as the
defective module is removed.
To replace the fan assembly:
Move any interface cables away from the fan assembly.
Loosen the captive screw on the fan assembly and slide the assembly out of the
chassis
(Figure
3-4).
The fans might still be turning when you remove the fan assembly from the
chassis. Keep fingers, screwdrivers, and other objects away from the openings
in the fan assembly's housing.
Cisco 10005 ESR Hardware Overview and Maintenance Guide
Removing and Replacing Field-Replaceable Units
3-9