Activating The Tube Collector Function (F1); Activating The Anti-Freeze Function (F2) - Honeywell ASC02-01WM Installation And Operating Instructions Manual

Temperature differential controller 2 inputs, 1 output
Table of Contents

Advertisement

ASC02-01WM
8.2.6
NOTE
CONDITION FOR
ACTION
8.2.7
NOTE
EN2B-0365GE51 R0710

Activating the tube collector function (F1)

Incorrectly setting the controller can compromise the efficiency of
the solar energy system. Therefore, only activate the tube
collector function if the construction of the collector does not allow
its temperature to be recorded immediately and / or accurately (in
some cases there are no immersion sensors; the sensor is
outside the collector pipe).
The F1 menu is open
► Press the SET button for approx. 2 seconds until either "oFF"
or "on" flashes.
► Toggle between "oFF" and "on" using the
► To save the setting, press the SET button.

Activating the anti-freeze function (F2)

CAUTION
System can freeze despite the activated anti-freeze function!
During a power outage, the anti-freeze function does not
operate.
During long-term periods of frost (due to restricted water
tank heat storage).
If collectors are mounted in locations exposed to wind.
► If frost is expected for a long-term period of time, only operate
the system with heat transfer fluid.
For further information see chapter 7.5.
Incorrectly setting the controller can compromise the efficiency of
the solar energy system.
► Only activate the anti-freeze function for solar energy systems
that are not filled with anti-freeze.
Operation
or
buttons.
27