Cisco MDS 9000 Series Configuration Manual page 189

Hide thumbs Also See for MDS 9000 Series:
Table of Contents

Advertisement

Managing Modules
LED
Link
This table describes the LEDs for the Cisco MDS 9200 Series interface module.
Table 27: LEDs on the Cisco MDS 9200 Series Interface Module
LED
Status
OL-29291-02
Status
Solid green
Solid yellow
Flashing yellow
Off
Status
Green
Orange
Red
Cisco MDS 9000 Family NX-OS Fundamentals Configuration Guide
Identifying Module LEDs
Description
Link is up.
Link is disabled by software.
A fault condition exists.
No link.
Description
All diagnostics pass. The module
is operational (normal initialization
sequence).
The module is booting or running
diagnostics (normal initialization
sequence).
or
The inlet air temperature of the
system has exceeded the maximum
system operating temperature limit
(a minor environmental warning).
To ensure maximum product life,
you should immediately correct the
environmental temperature and
restore the system to normal
operation.
The diagnostic test failed. The
module is not operational because
a fault occurred during the
initialization sequence.
or
The inlet air temperature of the
system has exceeded the safe
operating temperature limits of the
card (a major environmental
warning). The card has been shut
down to prevent permanent
damage.
171