Identifying Module LEDs

Identifying Module LEDs
This table describes the LEDs for the Cisco MDS 9200 Series integrated supervisor modules.
Table 26: LEDs for the Cisco MDS 9200 Series Supervisor Modules
LED
Status
Speed
Cisco MDS 9000 Family NX-OS Fundamentals Configuration Guide
170
Status
Green
Orange
Red
On
Off
Flashing
Managing Modules
Description
All diagnostics pass. The module
is operational (normal initialization
sequence).
The module is booting or running
diagnostics (normal initialization
sequence).
or
The inlet air temperature of the
system has exceeded the maximum
system operating temperature limit
(a minor environmental warning).
To ensure maximum product life,
you should immediately correct the
environmental temperature and
restore the system to normal
operation.
The diagnostic test failed. The
module is not operational because
a fault occurred during the
initialization sequence.
or
The inlet air temperature of the
system has exceeded the safe
operating temperature limits of the
card (a major environmental
warning). The card has been shut
down to prevent permanent
damage. The system will be shut
down after two minutes if this
condition is not cleared.
2-Gbps mode and beacon mode
disabled.
1-Gbps mode and beacon mode
disabled.
Beacon mode enabled.