05.08
© Siemens AG 2008 All Rights Reserved
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) – 05.2008 Edition
10.2 NCK safety alarms for SINUMERIK 840D sl
1004
Violated plausibility, user agreement
S Although the user agreement was already set, an attempt was
made to set it again.
S The user agreement is set although the axis has still not been ref-
erenced.
1005
When activating the SGEs test stop selection, the shutdown path test
cannot be carried out because the pulses have already been cancelled.
Remedy
Check the starting conditions for carrying out the test and if required,
correct. In the commissioning phase, it is also possible that there is
incorrect parameterization (or wiring) for the feedback signal regarding
pulse cancellation (MD 36975).
1007
Only in the drive: see F01711
Cyclic communications between the PLC and drive have failed.
Remedy
If required, replace the hardware, drive control.
Check the drive bus and PLC
1008
Only in the drive: see F01711
Data transfer error between the PLC and drive.
Remedy
If required, replace the hardware, drive control.
Check the drive bus and PLC
1009
After activating the SGEs test stop selection, the pulses have still not
been cancelled after timer MD 36957/p9557 has elapsed.
Remedy
Check the parameterization for the timer – it is possible that the value
has been selected too low.
1011
The internal status "acceptance test status" when using the acceptance
test support indicates different states for the NCK/drive for at least 2
seconds.
1012
Only in the drive: see F01711
The actual value has violated the plausibility for the higher–level con-
trol. The redundant coarse position does not match the actual value.
Remedy
Upgrade the Sensor Module software.
1014
NCK axis number from the PLC–SRAM and NCK axis number from the
boot operation are different.
Remedy
Re–establish data consistency using a Power On.