Troubleshooting Error Messages - Philips VL3000 Service Manual

Spot & wash; q spot & wash luminaires
Table of Contents

Advertisement

Troubleshooting
Error Messages
If a problem occurs during luminaire calibration, at the end of the calibration sequence the Menu
Display will cycle through any applicable error message(s), one a time until the end of the list is
reached. To review the error messages again, it will be necessary to access them using the Status
function. (Refer to
associated with the error messages.)
To access error messages:
Step 1. Press [Menu].
Step 2. Press [Up] / [Down] arrows until Fixture appears. Press [Enter].
Step 3. Press [Up]/ [Down] arrows to access Status. Press [Enter]. (Display will now scroll
through any error messages or display OK if there are no errors.)
02.96 78.001 0 G
"Troubleshooting Guide" on page 16
Table 2-1: Error Messages
Display
OK
Pan/No Sens
Pan/Encoder/Fail
Tilt/No Sens
Tilt/Encoder/Fail
Index1/No Sens
Gobo1/No Sens
Index2/No Sens
Gobo2/No Sens
Index3/No Sens
Gobo3/No Sens
Dimmer/No Sens
Blue/No Sens
Amber/No Sens
Magenta/No Sens
ColWheel/No Sens
CTO/No Sens
Zoom/No Sens
Edge/No Sens
T
ROUBLESHOOTING
for a list of possible causes and remedies
Message...
No Errors Found
Pan sensor not found.
Pan encoder failure.
Tilt sensor not found.
Tilt encoder failure.
Gobo 1 Index sensor not found.
Rotating Gobo 1 sensor not found.
Gobo 2 Index sensor not found.
Rotating Gobo 2 sensor not found.
Gobo 3 Index sensor not found.
Rotating Gobo 3 sensor not found.
Dimmer sensor not found.
Blue sensor not found.
Amber sensor not found.
Magenta sensor not found.
Color wheel sensor not found.
CTO sensor not found.
Zoom sensor not found.
Edge sensor not found.
: E
M
RROR
ESSAGES