VARI
LITE® - VL3000™ & VL3000™Q S

UV Filter Bulkhead Assembly

22.9678.0639 Rev G (VL3000)
22.9678.0617 Rev A (VL3000Q)
Refer to
Figure 3-5
No.
Item
1
10.9678.0634
2
10.9678.0648
3
41.9678.0608
41.9678.1160
4
53.6530.0002
3
2
86
ERVICE
Qty.
UM.
Description
1
EA
UV FILTER BULKHEAD
2
EA
CLIP, UV GLASS
1
EA
UV/IR FILTER, 3.00" X 3.00" (VL3000 Only)
1
EA
UV/IR FILTER, ENHANCED (VL3000Q Only)
4
EA
RIVET, 1/8 OD POP,.063-.125 GRIP, ALUM
1
Figure 3-5: UV Filter Bulkhead Assembly
M
ANUAL
4
(x4)
UV Filter Installation
1.
Install filter with marks indicating IR coating side of
filter facing up and located outside of circular
cutout in bulkhead.
2.
Apply a drop of Loctite 5083 NUVA-SIL Curing
Silicone to each corner of filter. Drop size to
produce 0.25" diameter circle of adhesive when
filter is secured.
3.
Position UV filter in between 8 raised locating tabs
on bulkhead and attach using UV glass clips and
rivets as shown.
Be careful not to damage UV filter (chip, scratch,
crack, etc.) during installation.
02.96 78.001 0 G