4.5.2 Function of Basic Instruction

◎ Function D (d) Command
Sample 1: I1─D ──[ Q1
I1
D
Q1
Sample 2: i1─d ──[Q1
I1
I1 is the reverse phase of i1.
i1
d1
Q1
◎ NORMAL ( - [ ) Output
I1 ── [Q1
I1
Q1
◎ SET ( ) Output
I1 ──
Q1
I1
Q1
◎ RESET ( ) Output
I1 ──
Q1
I1
Q1
◎ P Output
i1 ──PQ1
I1
I1 is the reverse
phase of i1.
i1
Q1
OFF
OFF
OFF
OFF
ON
OFF
ON
OFF
ON
OFF
OFF
OFF
OFF
OFF
ON
OFF
ON
OFF
ON
OFF
ON
ON
One complete scan period
ON
ON
OFF
One complete scan period
ON
ON
ON
ON
ON OFF
ON
4-56
Chapter 4 Software Index
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
OFF
OFF
ON OFF
OFF
OFF

Advertisement