Revision 0 10640I00.Slk - Honeywell KHF 1050 System Installation Manual

Hf communication system
Hide thumbs Also See for KHF 1050:
Table of Contents

Advertisement

Preliminary - Subject to Change Without Notice
power supply with a circuit breaker with not less than 25
Amp rating.
6.C.(3) Grounding Requirements
Except for the ground provided by the feedline coax
shield, bonding should not be done with braided wire but
with solid conductive straps, typically one inch wide.
6.C.(4) After a location has been selected, remove the mounting
tray from the four shock mounts.
6.C.(5) Place each shock mount dead center over each center tap
position.
6.C.(6) Drill four #8 holes per each shock mount.
6.C.(7) Thoroughly clean the mounting surface where the bonding
straps will be attached. If the surface is aluminum, apply
Alodine #1001 per Section 6.A.(1).
6.C.(8) Mount the shock mounts to the mounting surface with four
each # 8-32 fasteners and lock nuts, installing the ground
straps under the appropriate shock mounts.
6.C.(9) Attach the mounting tray to the four shock mounts,
installing the two tray ground straps.
6.C.(10) With the mounting tray secured, locate a point on the
airframe structure near the antenna feedthru for attaching
a unit to airframe ground strap. Drill two #6 holes, clean
and apply Alodine per section 6.A.(1). Connect a ground
strap between this point and the KPA 1052 Power Amplifier.
NOTE: This strap shold not be braided wire, but a solid
6.C.(11) Place the KPA 1052 Power Amplifier unit into the mounting
tray and secure it in place with two knurled knobs.
Provisions for safety wire installation is provided, if
desired.
6.D. KRX 1053 Receiver/Exciter Installation
6.D.(1) Select a mounting location, referring to Section 5.B.(3).
6.D.(2) After a location has been selected, remove the mounting
tray from the four shock mounts.
Revision 0
10640I00.SLK
N
KHF 1050 SYSTEM INSTALLATION MANUAL
strap.
23-10-09
Page 2039
Mar/2003

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents