Alarm output duration: Set the duration of the linkage alarm output after being
triggered (in seconds), the range of the duration is 0~86400s.0 means that there is
no limit for alarm output.
Snap: When alarm is triggered, the device SD card will be driven to snap pictures.
The pictures can be saved via E-mail sending or FTP uploading. For snapping
parameters, if the number of pictures snapped at one time is set as 10, and the
snapping interval is 1 second, that means when there is an alarm, 10 pictures will
be snapped and the interval between each picture is 1 second.
Record: When alarm is triggered, the device SD card will be driven to record
images. The record files can be saved via E-mail sending or FTP uploading.
After setting all the parameters, click Save to make the parameters valid.

Dome Camera

Camera Setting
Figure 3-39
See
Record file packet time equals duration of alarm add the
record time set in Linkage
When network failure occurs, E-mail sending and FTP
uploading cannot be performed, the pictures and recorded
files will be stored in SD card. E-mail sending and FTP
uploading will resume after network is recovered.