Conditions Of Ce Marking - Panasonic VF200 Instruction Manual

Table of Contents

Advertisement

Conditions of CE Marking

VF200 inverter meets requirements of overvoltage category II stipulated in
EN 61800-5-1 standard.
A transformer subject to basic insulation shall be installed between inverter and
power supply.
The insulated transformer shall use the product in compliance with EN standard
or IEC standard (with basic insulation at least).
Overall system shall meet requirements of overvoltage category III stipulated in
EN 61800-5-1 standard.
According to EMC regulation, the inverter is not an independent operating unit.
The overall system may not be evaluated based on electro magnetic compatibility,
until the overall system is composed of the inverter and device with filter.