Appendix Function Parameter List
●Please use the inverter in the following conditions when set to "auto torque
boost".
・The motor must be the squirrel-cage induction motor for general purpose.
・Please select the inverter with the capacity equivalent to or 1 level higher
than motor capacity.
Example 1) Please select a 0.75 kW inverter for motor ranging from 0.4 kW
to 0.75 kW.
Example 2) Please select a 1.5 kW inverter for motor ranging from 0.75 kW
to 1.5 kW.
・The motor must be a 2-pole, 4-pole or 6-pole one.
・It must be operated under standalone mode (i.e., one motor is driven by
one inverter).
・The maximum wiring length between the inverter and motor must not
exceed 30 m.
If the above conditions are not satisfied, sound operation performance cannot
be achieved.
When vector control is selected, the output frequency ranges from 1 Hz to 120
Hz.
・During auto torque boost setting, the output frequency ranges from 1 Hz to
120 Hz.
Related parameters: P005, P008, P036 to P040, P116, P118 to P123