Precautions on European Standard Directives

1. CE Marking labeled on the inverter is based on Low Voltage Directive.
2. Adaptability to EMC Directive shall be determined in a complete plant equipped
with the inverter.
3. Inverter's control circuit terminals are only basically insulated (protection against
electric shock I, overvoltage category II, pollution degree 2).
To meet requirements of CE Marking, final product shall be subject to insulation.
4. Power supply input end of the inverter shall be equipped with protection devices
for overcurrent, short circuit and leakage of electricity.
5. Main circuit wiring shall be connected with ring-type compression terminals.
Main circuit wiring 200V type : (L, N, U, V, W)
6. The inverter is only used for fixed installation, not for other occasions.
7. Adaptability to Low Voltage Directive for the inverter
1) Protection against Electric Shock: I
2) Overvoltage category: II
3) Pollution degree: 2
8. The capacity of relay output terminal mark A, B, C is 30V DC, 0.3A.
9. Make sure to ground the supply neutral. (only 400V-type)
400V type : (R/L1, S/L2, T/L3, U, V, W)
277