Appendix Function Parameter List
P033
Stop Frequency during Forward/Reverse Run Operation
DC Brake Time during Forward/Reverse Run Operation
P034
DC Brake Level during Rorward/Reverse Run Operation
P035
DC brake can be applied when the inverter output frequency drops below
"P033: Stop Frequency during Forward/Reverse Run Operation" during
forward/reverse run operation.
■ Parameter P033: Stop Frequency during Forward/Reverse Run Operation
Data setting range
(Hz)
■ Parameter P034: DC Brake Time during Forward/Reverse Run Operation
Data setting range (s)
* DC brake will be not applied if "0000" is set.
■ Parameter P035: DC Brake Level during Forward/Reverse Run Operation
Data setting range (s)
* The setting increment is "5". The larger the value is, the stronger the braking
force will be.
・The frequency for applying DC brake is set with parameter "P033: Stop
Frequency during Forward/Reverse Run Operation".
・"P033: Stop Frequency during Forward/Reverse Run Operation" is valid only
170
0.5 to 60.0
0000·0.1 to 120.0
0 to 100