Appendix Function Parameter List
P135
Communication Protocol Select
Communication Station No. Setting
P136
Communication Speed Setting
P137
Stop Bit Length
P138
Important parameters necessary for sending commands to inverter through
communication can be set.
■ P135: Communication Protocol Select
VF200 is based on two protocols: MEWTOCOL-COM and Modbus (RTU).
Either protocol can be selected.
Setting value
0
1
■ P136: Communication Station No. Setting
Data setting range
■ P137: Communication Speed Setting
Setting value
48
96
192
384
■ P138: Stop Bit Length
Setting value
1
2
■ P139: Parity Check
Setting value
0
1
2
254
Details of function
MEWTOCOL-COM
Modbus (RTU)
1 to 31
Details of function
4800 bps
9600 bps
19200 bps
38400 bps
Details of function
1 bit
2 bit
Details of function
Without parity check
Odd parity
Even parity
P139
Parity Check
Timeout Sensing
P140
Wait-to-send Time
P141
Judging Time for TEXT Completion
P142