Analog And Pwm Output Function Select - Panasonic VF200 Instruction Manual

Table of Contents

Advertisement

P095
Current Sensing Level
Current Sensing Delay Time
P096
Open-collector 1, 2 and relay output can be used to set current sensing level
and delay time when current sensing signal is output.
■ Parameter P095: Current Sensing Level
Data setting range (A) 0.1 to 100.0
■ Parameter P096: Current Sensing Delay Time
Data setting range (s)
・Current sensing delay time refers to the delay time for a signal to switch from
OFF to ON.
The delay time for a signal to switch from ON to OFF is about 100 ms (fixed
value).
Related parameters: P090 to P092
P097

Analog and PWM Output Function Select

Functions of "0 to 10 V voltage signal" and "output state signal (PWM)" output
from control circuit terminal No.17 and terminal No.10 to No.12 can be set
respectively.
Setting
value
Signals in proportion to output
0
frequency are output.
Signals in proportion to output
1
current are output.
0.1 to 10.0
Details
Appendix Function Parameter List
217