Perform the Audio Test as follows:
ICON
1. Press the Audio Test icon; "Testing.." is
displayed while beeps sound from the
speaker.
At the conclusion of the test, a pop-up "Confirmation
Window" is displayed with the question "Did you
hear Beeping?"

LED Test

Perform the LED Test as follows:
ICON
1. Press the LED Test icon; "Testing.." is
displayed while the 3 LEDs light
sequentially, top to bottom (red, green,
yellow), 5 times.

Calibration Test

If the Touch Screen requires recalibration, do the following:

Z-Wave Test

ICON
1. Select the Calibration icon and using a
stylus, follow the screen directions by
pressing a series of crosshairs (+) and
boxes ( ) on the screen until done.
2. If the test was successful, press OK; the
screen returns to the Keypad Test screen.
This procedure is for Z-Wave test purposes only.
Role shifting is the process of shifting primary and secondary keypads (controllers). The secondary
controller becomes the primary controller with the ability to enroll Z-Wave devices. This is useful when
the primary controller is in a fixed location and the Z-wave device is not easily accessible (but within
Z-Wave range). To perform the role shifting Z-Wave Test, do the following:
ICON
1. Press the Advanced Setup icon.
2. Enter your Authorized Code.
3. Press the Keypad Test icon.
4. With the status of the controller in the "P"
User System Setup (cont'd)
ACTION
ACTION
ACTION
ACTION
30
NOTES
When you press Yes, "Passed" is displayed in the
test status column on the "Diagnostics" screen.
When you press No, "Failed" is displayed in the
test status column on the "Diagnostics" screen.
NOTES
At the conclusion of the test, a pop-up
"Confirmation Window" is displayed with the
question "Did you see chasing LED pattern?"
If you press Yes, "Passed" is displayed in the test
status column on the "Diagnostics" screen.
If you press No, "Failed" is displayed in the test
status column on the "Diagnostics" screen.
NOTES
A pop-up message displays:
Touch screen calibration
Touch crosshair to calibrate
If the Calibration test was successful, a confirmation
screen appears stating: "Congratulations
Calibration Success"
If the test was unsuccessful, an error message
appears stating: "Calibration failed, do you want
to retry?" Yes or No.
NOTES
Note: The status of the controller can only be
changed from Primary to Secondary controller
when no devices are enrolled.
Use the delete device or reset controller function
to remove enrolled devices.