4.2.4 Domestic Hot Water Menu

4.2.4.1 DHW Economy Temperature

4.2.4.2 Legionella Protection-Day

rices and delivery to your door visit MyTub Ltd - 0845 303 8383 - www.mytub.co.uk - info@mytu
Settings:
NOTE
Function
Factory setting
Setting range
NOTE
Factory setting
Setting range
With the flashing reset display PARAM. - RESET
press the rotary pushbutton.
The flashing reset ready indication (SET) appears.
Press the rotary pushbutton for approx. 5 s.
In case of a reset, the confirmation RESET OK appears
briefly, then -in order of feedback- the first parameter in
the relevant menu is called.
This menu comprises all the parameters necessary for
the programming of the DHW circuit with the exception of
the DHW time program.
This menu can be called only if the heating technician
has activated a DHW loading pump or a DHW circulation
pump.
This parameter determines the temperature in the
domestic hot water heater between the heating cycles in
automatic mode.
40 °C
10 °C...DHW normal temperature setting
If a DHW thermostat is used to determine the water
heater temperature, this parameter is skipped.
OFF
OFF, MON. to SUN., ALL
39
SDC / DHC 43

EN2H-0220 GE51 R1005