Chapter 3 Appendix
Detected that Intel(R) Node Manager is in Recovery Mode.
[Recommended action]
Unplug the power cord of server, wait for 30 seconds, and reboot the server.
If it does not resolve your problem, contact your sales representative.
The following error messages are not shown on display unit, but registered in IPMI system event log.
A800: Memory not detected
[Description]
Valid DIMM could not be detected.
*No DIMM was detected.
*Detected that Unbuffered DIMM and Registered DIMM are installed together.
*Failed DIMM was detected, but available DIMM could not be detected.
*Available DIMM could not be detected.
[Recommended action]
Restart the server.
If it does not solve your problem, make sure that DIMM is installed in correct slot.
If it does not solve your problem, check the type of DIMM.
If it does not solve your problem, check installation status of DIMM.
If it does not solve your problem, remove DIMM and install it again.
If it does not resolve your problem, contact your sales representative.
A801: Useful Memory not detected
[Description]
Indicates that no DIMM available for this configuration is installed.
[Recommended action]
Restart the server.
If it does not solve your problem, check installation status of DIMM.
If it does not solve your problem, remove DIMM and install it again.
If it does not resolve your problem, contact your sales representative.
B200: Onboard VGA - PCIe Link Failure
[Description]
A connection failure was detected on PCIe bus of onboard VGA.
[Recommended action]
Restart the server.
If it does not resolve your problem, contact your sales representative.