Main code 91 : Abnormality of communication system or interface system
Main
Sub
Detected contents
code
code
91
125
Communication error between system control and keyboard (detected by SY).
130
System control detected abnormality of ROM.
131
System control detected abnormality of external memory.
132
System control detected abnormality of internal memory.
133
System control detected abnormality of common memory for SERVO.
134
System control detected abnormality of common memory for SPCON.
139
System control detected abnormality of EEPROM (IC8 on the DR-428BG board).
13A
Detected abnormality in NVRAM.
13B
Detected abnormality in Resetable Hour Meter.
13C
Detected abnormality in Volume adjustment data area.
13F
Communication error to MIC.
145
Communication error between system control and servo.
165
Communication error between system control and MONTA.
175
Communication error between system control and SPCON.
195
Communication error between system control and the SW microprocessor.
1A5
Communication error between system control and external keyboard.
1D5
Communication error between system control and the DV microprocessor.
1E5
Communication error between system control and the SDI-94 board.
1F5
Communication error between system control and AVANT.
215
Communication error between system control and keyboard (detected by KY).
225
LCD driver writing error
239
EEPROM (KY-616 board, IC300) access error
430
Servo main detect abnormality of ROM.
431
Servo detected abnormality of external memory.
439
Detected abnormality in the servo adjustment data area.
43B
Detected abnormality in Unresetable Hours Meter.
455
Communication error between servo main and servo sub microprocessors.
463
Communication error between servo main and MONTA.
539
Detected abnormality in the EQ data area.
603
Communication error between MONTA and Villenuve.
605
Villenuve initialization error
613
Communication error between MONTA and system control.
643
Communication error between MONTA and servo main.
680
Access error of MONTA to Torino-Flash.
689
Torino-Flash initialization error
693
Communication error between MONTA and Rota-cont.
695
Rota-cont initialization error
6A5
Torino initialization error
6B5
Estoril initialization error
6C5
Dia initialization error
6F5
SAVER initialization error
730
SPCON detected abnormality of ROM.
731
SPCON detected abnormality of external RAM (IC503 on the SSS-12 board).
732
SPCON detected abnormality of internal RAM.
733
SPCON detected abnormality of the communication IC (IC503 on the SSS-12 board) with SY.
734
SPCON detected communication error (IC401 on the SSS-12 board) with SV.