Replacement
1. Removing the M stop drive plate
assembly
Remove the two precision screws then remove
the M stop drive plate assembly.
2. Replacing the M stop solenoid
(1) Remove the two precision screws then
remove the M plunger plate assembly.
n
Be careful not to lose the iron core and the
compression coil spring because they drop
when the M plunger plate assembly is
removed.
(2) Install the compression coil spring to the iron
core and insert it into the hole of the new M
stop solenoid.
(3) Insert the pin of the iron core pin into the two
notches of the M plunger plate assembly and
fix it tentatively with the two precision
screws.
6-28
Notches
Compression coil spring
Iron core
Pins
Precision screws
P1.4 x 3.5
M stop drive plate assembly
Precision screws
P2 x 2
M plunger plate
assembly
M stop
solenoid
Hole
HVR-1500