The combined RCTUCl/Dl PCBs (Release l ) ,
(Release 3).
There are two versions of RCTUC: RCTUCI
and RCTUC3. RCTUCI can be used with
with RCTUD 1, 02 and 03.
Each of these units supports a distinct number of
cabinets, stations, and lines. The RCTUA (1 and 3)
PCB can support only one cabinet, and up to 32
stations or 16 CO lines. The RCTUB1, RCTUB2, and
and up to 80 stations or 48 CO lines. The
operate together to support up to six cabinets, and up
to 240 stations or 144 CO lines.
Additionally, each of the common control units can
support a separate set of features. Refer to
Chapter I-Configuration for more common control
unit capacity and feature information.
o f
Each
the common control units (except RCTU BB)
may be equipped with an RRCS (4, 8, or 12) to
interpret Dual-Tone Multi-Frequency (DTMF) signals
transmitted from tie/DID lines and standard telephone
ports. The common control units also provide an
interface (along with a volume control) for a Music-on-
hold (MOH)/Background Music (BGM) source.
RCTU controls, indicators, and interface connectors
are shown in Figure 4-4 through 4-14 and described in
Table 4-1 through 4-1 1.
4.3.1 Common Control Unit
Options
The common control units (RCTUA, RCTUA3,
RCTUB, RCTUB2, RCTUBA/BB, R C T U C I / D I ,
hardware options:
Internal Options
RRCS-12)
There are three RRCSs: the RRCS-4 has four DTMF
receiver circuits; the RRCS-8 has eight receiver
circuits; and the RRCS-12 has 12 receiver circuits.
The RCTUAI and RCTUA3 can support up to 12
DTMF receiver circuits; the RCTUB, RCTUB2, and
RCTUBA have up to 12 circuits; and the
4-4
RCTUC and one RRCS on RCTUD).
Install the appropriate RKYS (IA, 2A, 3A or 4A) per
Figure 4-3, to enable the built-in Auto Attendant,
Automatic Call Distribution (ACD), Management
Information System (MIS) to ACD, and/or Open
Architecture for ACD.
Hardware
External Option
Each of the common control units (except RCTUD and
RRCS-8,
RCTUBB) has a trim potentiometer (VR1) to adjust the
volume of the MOH/BGM source connected to the
common control unit. The volume control
potentiometer and the MOH/BGM interface are on the
RCTUA (1
RCTUC PCBs.
card
RKYS-1 (Works with all RCTU processors to
provide auto attendant.)
RKYS-2 (Works with all processors except
attendant and ACD.)
RKYS-3 (Works with all processors except
attendant, ACD, and ACD/MIS.)
capability for ACD calls.)
Note:
and above.
IMPORTANT!
It is not necessary to run any special
programs (i.e. Program
installed. RKYS can be installed before or
after system initialization, and, before or after
the customer database is entered. The
immediately when RKYS is installed.
However, configuration programs for AA and
ACD must be run for the feature to operate.
Volume Control (VRI)
or
RCTUB (1 or 2), RCTUBA and
3),
provide all
to
03)
when RKYS is
January 1996

Hide quick links:

Advertisement

Table of Contents