Yamaha DME64N Owner's Manual page 101

Dme designer
Hide thumbs Also See for DME64N:
Table of Contents

Advertisement

The specified [Min] and [Max] parameter values are alternately selected each time the voltage
applied to GPI IN drops from above to below the median voltage.*
Example: Relationship between the voltage applied to GPI IN and the Fader Level when [Fader Level]
is set in the [Parameter] box.
Max. voltage applied to GPI IN
Min. voltage applied to GPI IN
• [Scene Change]
GPI input can be used to recall a specified scene.
[Parameter] specifies the number of the scene to be recalled.
[Min] and [Max] are not available.
[Terminal] determines how the GPI input voltage will affect the specified parameter.
The scene specified by [Parameter] will be recalled each time the voltage applied to GPI IN rises
from below to above the median voltage.*
Max. voltage applied to GPI IN
Min. voltage applied to GPI IN
The scene specified by [Parameter] will be recalled each time the voltage applied to GPI IN drops
from above to below the median voltage.*
Max. voltage applied to GPI IN
Min. voltage applied to GPI IN
Same as
.
Same as
.
[Min] parameter value
[Max] parameter value
Median voltage
Trigger
Trigger
Median voltage
Chapter 3 Main Panel Window
[Min] parameter value
Median voltage
DME Designer Owner's Manual
101

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dme24nDme4io-cDme8i-cSp2060Dme8o-cDme designer 2.0

Table of Contents