I/O Card (For Dibos Micro) - Bosch DB18C3100R2 Installation Manual

Installation guide
Table of Contents

Advertisement

28
en | Device Connections
3.2.4

I/O Card (for DiBos micro)

The following can be set for the I/O card:
The I/O card must be removed to change the bridge settings.
1
2
3
4
F.01U.033.308 | V7 | 2009.09
the relay outputs (NO = normally open, NC = normally closed)
the malfunction outputs (NO = normally open, NC = normally closed)
Cable for monitor output A and monitor output B (the cables are numbered).
Cable number 1 = Monitor A
Cable number 2 = Monitor B
Connecting cable for 12 alarm inputs, 12 relay outputs, 3 biphase and 1 malfunction
output (for assignment, see table below)
16 relay outputs:
The setting is printed on the PCB.
Relay outputs 1–8: open (NO = normally open)
Relay outputs 9–16: closed (NC = normally closed)
Malfunction output: The setting is printed on the PCB.
Top bridge position: Open (MAL NO = malfunction normally
open)
Bottom bridge position (position when delivered): Closed (MAL
NC = malfunction normally closed)
Installation Guide
DiBos/DiBos Micro
Bosch Sicherheitssysteme GmbH

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

DibosDibos micro

Table of Contents