Grabber Card For Dibos - Bosch DB18C3100R2 Installation Manual

Installation guide
Table of Contents

Advertisement

DiBos/DiBos Micro
3.1.3

Grabber Card for DiBos

Looped through inputs may not be terminated. When a grabber card is retrofitted, the grabber
identification (grabber 1, grabber 2 etc.) must be set.
1
2
3
Bosch Sicherheitssysteme GmbH
Grabber identification:
The setting for grabbers 1 - 5 is printed on the PCB.
0 = Grabber 1
1 = Grabber 2
2 = Grabber 3
3 = Grabber 4
4 = Grabber 5
Loopthrough cable plug
Termination when loopthrough cable is used:
1 = Switch position left: input terminated (position when
delivered)
2 = Switch position right: open, not terminated
3 = Topmost switch: for camera input 1 etc.
Note:
The positions relate to the illustration above.
Installation Guide
Device Connections | en
23
F.01U.033.308 | V7 | 2009.09