• [Parameter Value Edit]
Allows component parameters to be changed via GPI input.
In this case [Parameter] is used to select the parameter to be controlled.
[Min] and [Max] specify the range over which the parameter can be changed.
[Terminal] determines how the GPI input voltage will affect the specified parameter.
and
specify continuous control of continuously-variable parameters from an external
fader, knob, or similar device.
and
specify on/off control of 2-state parameters via an external switching device.
The parameter value changes in proportion to the voltage applied to the GPI input.
The minimum voltage applied to GPI IN will produce the specified [Min] parameter value, and the
maximum voltage applied to GPI IN will produce the specified [Max] parameter value, with
intermediate voltages produced the corresponding intermediate parameter values.
Example: Relationship between the voltage applied to GPI IN and the Fader Level when [Fader Level]
is set in the [Parameter] box.
Max. voltage applied to GPI IN
Min. voltage applied to GPI IN
The parameter value changes in inverse proportion to the voltage applied to the GPI input.
The minimum voltage applied to GPI IN will produce the specified [Max] parameter value, and the
maximum voltage applied to GPI IN will produce the specified [Min] parameter value, with
intermediate voltages produced the corresponding intermediate parameter values.
Example: Relationship between the voltage applied to GPI IN and the Fader Level when [Fader Level]
is set in the [Parameter] box.
Max. voltage applied to GPI IN
Min. voltage applied to GPI IN
The specified [Min] and [Max] parameter values are alternately selected each time the voltage
applied to GPI IN rises from below to above the median voltage.*
Example: Relationship between the voltage applied to GPI IN and the Fader Level when [Fader Level]
is set in the [Parameter] box.
Max. voltage applied to GPI IN
Min. voltage applied to GPI IN
The specified [Min] and [Max] parameter values are alternately selected each time the voltage
applied to GPI IN drops from above to below the median voltage.*
Example: Relationship between the voltage applied to GPI IN and the Fader Level when [Fader Level]
is set in the [Parameter] box.
Max. voltage applied to GPI IN
Min. voltage applied to GPI IN
[Max] parameter value
[Min] parameter value
[Max] parameter value
[Min] parameter value
[Max] parameter value
[Min] parameter value
[Max] parameter value
[Min] parameter value
Chapter 3 Main Panel Window
Median voltage
[Max] parameter value
[Max] parameter value
Median voltage
DME Designer Owner's Manual