Yamaha DME Designer Owner's Manual page 67

Version 1.2
Hide thumbs Also See for DME Designer:
Table of Contents

Advertisement

[Recall Safe] Button
Before performing a recall, you can check the contents of the scene selected on the list, and set
components that will not be read. This is used when there are components you do not want
changed by the scene recall.
When you click this button, the "Recall Safe" dialog box will be displayed.
Checkbox
All components included in the scene will be displayed. There is a checkbox to the left of each
component. Place a check next to the components you do not wish to have read by scene recall
(those you do not wish changed from their current status).
Press the [Select All] button to check all components, or the [Clear All] button to clear the checks
from all components.
Click the [OK] button. The dialog box will close and when the scene is recalled, all components,
except those checked, will be read.
NOTE
The components checked in the "Recall Safe" dialog box are the components that will not be read (that will be ignored).
If you want to read all components, there is no need to make settings in the "Recall Safe" dialog box.
"Recall Safe" is used when you want to keep some components with their current settings, while there are other
components you want to change according to the scene.
[Store] Button
Stores the contents of the current configuration into the scene selected in the list. If an empty scene
is selected and the contents stored there, a new scene is created. If a scene is already stored in
the selected scene number, it will be overwritten. If [Confirm Scene Store] is checked on the
[Application] tab of the "Preferences" dialog box, a confirmation dialog box will be displayed
before the scene is stored.
NOTE
The currently logged on user can store scenes at a security level equal to or lower than his or her own only.
NOTE
When the computer and DME unit are online, a scene stored in the DME Designer will also be stored on the DME unit,
regardless of the DME settings.
The DME utility display Misc. page [Scene Store] setting only affects store operation from the DME panel controls.
When a scene is stored, the configuration parameters at that time are saved as "preset
parameters." Presets are created automatically.
Chapter 3 Main Panel Window
Component Name
DME Designer Owner's Manual
67

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents