Table C-13: 1700 Series POST Error Messages
Error Code
1767- Slot x Drive
Array Option ROM is
not programmed
correctly.
1768-Slot X Drive
Array – Resuming
logical drive
expansion process
1769-Slot X Drive
Array – Drive(s)
disabled due to failure
during capacity
expansion. Select F1
to continue with
logical drives
disabled. Select F2 to
accept data loss and
to re-enable logical
drives.
HP Servers Troubleshooting Guide
Audible
Probable Source of
Beeps
Problem
None
Controller Option ROM
problem.
None
Power was lost while a
logical expansion
operation was performed.
None
Capacity expansion failed
due to one of the
following problems:
•
Array accelerator
removed or failed;
expansion progress
data lost
•
Expansion progress
data could not be
read from array
accelerator
•
Expansion aborted
due to unrecoverable
drive errors
•
Expansion aborted
due to array
accelerator errors
continued
Action
Upgrade firmware on all
Smart Array Controllers using
Options ROMPaq.
Download it from on the
following website:
www.compaq.com/support
No action required. This
message is displayed
whenever a controller reset or
power cycle occurs while
array expansion is in
progress.
Data lost while the array was
expanded; therefore, the
drives have been temporarily
disabled.
1.
Press the F2 key to
accept the data loss and
re-enable the logical
drives.
2.
Restore data from
backup.
3.
If caused by bad drive or
array accelerator failure,
replace drive or array
accelerator, as
appropriate.
POST Error Messages
continued
C-57