HP 1850R - ProLiant - 128 MB RAM Troubleshooting Manual page 237

Proliant server troubleshooting guide
Hide thumbs Also See for 1850R - ProLiant - 128 MB RAM:
Table of Contents

Advertisement

Table C-13: 1700 Series POST Error Messages
Error Code
1767- Slot x Drive
Array Option ROM is
not programmed
correctly.
1768-Slot X Drive
Array – Resuming
logical drive
expansion process
1769-Slot X Drive
Array – Drive(s)
disabled due to failure
during capacity
expansion. Select F1
to continue with
logical drives
disabled. Select F2 to
accept data loss and
to re-enable logical
drives.
HP Servers Troubleshooting Guide
Audible
Probable Source of
Beeps
Problem
None
Controller Option ROM
problem.
None
Power was lost while a
logical expansion
operation was performed.
None
Capacity expansion failed
due to one of the
following problems:
Array accelerator
removed or failed;
expansion progress
data lost
Expansion progress
data could not be
read from array
accelerator
Expansion aborted
due to unrecoverable
drive errors
Expansion aborted
due to array
accelerator errors
continued
Action
Upgrade firmware on all
Smart Array Controllers using
Options ROMPaq.
Download it from on the
following website:
www.compaq.com/support
No action required. This
message is displayed
whenever a controller reset or
power cycle occurs while
array expansion is in
progress.
Data lost while the array was
expanded; therefore, the
drives have been temporarily
disabled.
1.
Press the F2 key to
accept the data loss and
re-enable the logical
drives.
2.
Restore data from
backup.
3.
If caused by bad drive or
array accelerator failure,
replace drive or array
accelerator, as
appropriate.
POST Error Messages
continued
C-57

Advertisement

Table of Contents
loading

Table of Contents