Non-Numeric Post Error Messages Or Beeps Only; Non-Numeric Error Messages Or Beeps Only - HP 1850R - ProLiant - 128 MB RAM Troubleshooting Manual

Proliant server troubleshooting guide
Hide thumbs Also See for 1850R - ProLiant - 128 MB RAM:
Table of Contents

Advertisement

POST Error Messages
WARNING: To avoid potential problems, ALWAYS read the warnings and
cautionary information in your server-specific user documentation before
removing, replacing, reseating, or modifying system components.

Non-Numeric POST Error Messages or Beeps Only

Table C-2: Non-Numeric Error Messages or Beeps Only
Error Code
A Correctable
Memory Error
occurred prior to
this power-up
A Critical Error
occurred prior to
this power-up
A processor thermal
event occurred prior
to this power up,
Processor X
Beeps only
C-2
Audible
Probable Source of
Beeps
Problem
None
A memory module has
experienced an error
which, while recoverable,
has generated a
predictive failure warning.
None
A catastrophic system
error, which caused the
server to crash, has been
logged.
None
Processor X (1 or 2) has
reached an excessive
temperature and has
stopped operation.
2 long,
The power has cycled
2 short
because the temperature
is too hot. The processor
fan is not installed, or is
not spinning.
Action
Run Diagnostics to identify
and replace the appropriate
memory module.
Run Diagnostics. Replace
failed assembly as indicated.
Check the following
information:
The processor and
heatsink assembly is
properly installed.
Ambient temperature is
within an acceptable
range.
Check fans.
HP Servers Troubleshooting Guide
continued

Advertisement

Table of Contents
loading

Table of Contents