Test Error Codes

6600-6699, SCSI/IDE CD-ROM Drive Test Error Codes

The 6600 series of diagnostic error codes identifies failures with the CD-ROM
cabling, CD-ROM drive, adapter board, or system board assembly. Corrective action
may require replacement of the CD-ROM cabling, CD-ROM drive, adapter board, or
system board assembly.
Table B-13: SCSI/IDE CD-ROM Drive Test Error Codes
Error
Description
Code
6600-XX
CD-ROM ID failed
6605-XX
CD-ROM Read failed
6608-XX
SCSI controller test failed
B-14
Recommended Action
The following steps apply to error codes 6600-XX
through 6608-XX:
1.
Replace the CD-ROM media and retest.
2.
Check the signal cable and retest.
3.
Replace the signal cable and retest.
4.
Check the switch settings on the adapter board
(if applicable).
5.
Replace the SCSI controller (if applicable) and
retest.
6.
Replace the CD-ROM drive and retest.
7.
Replace the system board and retest.