52
en | Configuration
Menu Item
7.2.3
Set network mode
The network mode menu item (4B) is used to enable and disable the optical network
connections. When the transmitter is connected to a DCN Next Generation conference
system, the optical network connections must be enabled.
Menu Item
4B Network Mode
7.2.4
Set number of channels
Via sub-menu item 4C the number of channels that will be used can be set. Note that the
maximum number of channels depends on the transmitter type (4, 8, 16 or 32 channels) and
the chosen quality modes. When a DCN Next Generation or a DCN system is connected to the
transmitter, the number of channels can be automatically set by the connected system.
Menu Item
4C Nr. of Ch.
IOM-INT | V1.1 | 2010.12
Options
- Aux to All
- Test A
- Slave
Options
Mode:
- Disabled
- Enabled
Options
Nr. of channels
Installation and Operation manual
Description
The signals on the Auxiliary inputs are
distributed on one carrier to all channels.
A different test tone is distributed on each
channel. The frequency increases with
increasing channel number. For stereo
channels the tone for left and right will also be
different.
The radiator signal on the slave input is
looped-through to all radiators.
Description
Optical network connections disabled. Use
this mode when the transmitter is not used in
combination with DCN Next Generation.
Optical network connections enabled. Use
this mode when the transmitter is used in
combination with DCN Next Generation.