30
en | Installation
WARNING!
ICs and many other electronic components are susceptible to electrostatic discharge (ESD).
Take preventive measures when handling the interface modules. Keep the PCBs as long as
possible in their protective packing. Wear an anti-ESD bracelet.
5
3
Figure 5.4 Removing the main PCB and the rear panel (steps 1 - 5)
16
Figure 5.5 Removing the main PCB and the rear panel (steps 6 - 8)
1.
2.
3.
IOM-INT | V1.1 | 2010.12
1
6
8
2
7A
7B
7C
10
4
11
10
14
15
17
4
Remove the top cover of the transmitter housing.
If the transmitter contains an interface module (1): Remove the interface module
proceeding in reverse order of mounting. The mounting instructions can be found in
section 5.2 . Note that the distance studs of the transmitter module can remain in place.
If the transmitter does not contain an interface module: Remove the interface module
slot cover proceeding as described in section 5.2 .