g
EV Charging Station
After the old holding socket is removed, insert the replacement holding socket and tighten the
placement screws.
Re-connect the holding socket wire to the Phoenix connector, and re-connect the Phoenix connector
to the controller.
2.9.4 Service Door
Remove the service door.
Remove the door ground wire from door ground stud, shown in Figure 49.
Insert the new door and replace the ground wire to the door ground stud.
GE EV Charging Station User Manual
User Manual & Installation Instructions
WARNING: Make sure power to the EVSE is
disconnected before performing any task
Figure 49: Door Ground Connection
44 of 86