EV Charging Station
The cables must extend 16" to 24" above the wall surface, or according to local codes.
Pull L1, L2 and ground wire into the enclosure assembly through the conduit hub. Similarly pull the
communication cable into the enclosure assembly through the second conduit.
IMPORTANT: EV Charging Station is rated for 208-240V power only. The EVSE must be connected to a
grounded, metal, permanent wiring system, or an equipment grounding conductor. This should be run
with circuit conductors and connected to the equipment grounding bar or lead on the EVSE.
Connections to the EVSE shall comply with all applicable electrical codes and ordinances.
Install the enclosure on the wall-mounting bracket. Insert the threaded portion of the conduit hub into
the hole of the enclosure. Fasten the conduit hub using the nut. Fasten the enclosure to the wall-
mounting bracket using the self-sealing washers and nuts from inside the enclosure as indicated in
Figure 22.
Torque all the nuts as per the torque specification in Table 1.
WALL-MOUNT BRACKET
SLEEVE STUD ANCHOR WITH
HEX NUT
WALL-MOUNT UNIT
¼-20 HEX NUT, ¼:
SEALING WASHER
Connect L1, L2 to the fuse block and ground wire to the ground bar shown in Figure 23.
GE EV Charging Station User Manual
CONCRETE
ANCHOR
¾" CONDUIT HUB
Figure 22: Wall-Mount Installation, Exploded View
User Manual & Installation Instructions
(2) ¾" CONDUITS
23 of 86