Siemens SIDOOR ATD4 W Series System Manual page 191

Automatic door control units
Table of Contents

Advertisement

Parameter ID
Adjustment range
p90
0 ≙ deactivated
1 ≙ activated
p91
Write:
1 ≙ reset complete pa‐
rameter set (load all fac‐
tory defaults)
(As of V1.10)
2 ≙ Trigger restart of the
control unit
3 ≙ Reset full parameter
set and trigger restart of
the control unit
Read:
1 ≙ parameter set valida‐
ted and valid
0 ≙ parameter set invalid
and/or reset to factory
settings
p92
1 ≙ Reset FBLOCK config‐
uration
2 ≙ FBLOCK configuration
"Default input"
3 ≙ FBLOCK configuration
"Emergency stop 3 inp."
4 ≙ FBLOCK configuration
"Cold storage mode"
p93
1 ≙ load factory defaults
of the driving curve pa‐
rameter set
p95
0 ≙ deactivated
≥1 ≙ activated
ATD4xxW for industrial applications
System Manual, 06/2022, A5E51901827B AA
5.9 Operation and configuration of the control unit
Factory set‐
Unit
ting
0
0
Description
Write protection
Activates (1) or deactivates (0) write protection for all
driving curve parameters in the service menu.
As of V1.09: When write protection is activated via
parameter p90, the FBLOCK configuration, the force
for the learn run and the configuration of digital input
1 can no longer be changed via the operating menu.
As of V1.10: When write protection is activated, the
basic parameter cannot be changed via the operating
menu.
Note: All saved parameters are reset to factory set‐
ting! The control unit must be restarted for the factory
settings to take effect.
Note: A learn run is mandatory for "0" (parameter set
invalid or factory settings loaded)!
Default setting of FBLOCK configurations.
Note: If a value of 1 to 4 is written to this parameter,
all the FBLOCK parameters are preset to the selected
configuration.
The parameter can only be written. Reading always
supplies the value 0.
Note: All saved driving curve parameters are reset to
their factory defaults!
Loads driving curve parameters of the default
driving curve profile
In addition, the following parameters are reset:
p1202, p1203, p1204, p2104, p2105, p1242
Activation of a test run.
The reverse after block is switched off during the test
run. The test run is performed with the next drive
command. After the drive command has switched,
the test run is deactivated again, see section "4.3.12
Test run (as of V1.12) (Page 109)").
Controllers
189