Sensor Function Test - Siemens SIDOOR ATD4 W Series System Manual

Automatic door control units
Table of Contents

Advertisement

Controllers
5.7 Sensors and external sensor interface module
5.7.2

Sensor function test

When an ESPE or pressure sensitive edge is connected, equipment for a periodic test is required.
This test is intended to detect a dangerous failure before the dangerous function is used. If the
SIDOOR control unit's sensor logic is configured for an ESPE or pressure sensitive edge, the
"TestOUT" function test signal is output automatically via X100.1 (ATD420W, ATD430W) or X12
(ATD401W), see Relay and field bus interfaces (Page 136).
As soon as the system exits the "opened" end stop active in Normal mode (by door command),
a function test signal is automatically generated.
The appropriate configuration results in the following minimum test sequence duration:
t
test,min
The maximum possible test sequence duration before the test fails corresponds to t
x p4601.
The fault "8" is generated if the test operation fails. This fault must be acknowledged in
accordance with the control unit (cf. Fault management (Page 304)).
The following figure describes the timing of the "TestOUT" functional test signal generated by
the SIDOOR control unit and the timing requirements for the ESPE signal from the ESPE.
t
; t
1
t
reaction
t
discrepanc
y
Figure 5-6
170
= 2 × (t
+ t
reaction
discrepancy,min
Protective equipment is fault-free
A fault occurs when controlling the protective equipment
t
= t
= t
+ t
2
1
2
reaction
discrepancy
Internal reaction time and switching times
Discrepancy time of the OSSD t
Test point, evaluation of the OSSD signal
Signal profile 1 "low level" → fault-free
Signal profile 2 "high level" → fault
Sensor function test
)
= p4601
discrepancy
ATD4xxW for industrial applications
System Manual, 06/2022, A5E51901827B AA
, max = 2
Test