5.5 Relay and fieldbus interfaces
Task
The PROFIBUS module enables the SIDOOR ATD420W door controller to be connected to a
PROFIBUS fieldbus.
Interface
The ATD420W system is implemented as DP slave using the DP-V0 protocol. Data transfer is cyclic
with a class 1 DP master.
An ASIC of the "SPC3" type is used for interfacing to PROFIBUS. RS 485 in accordance with ANSI
TIA/EIA 485-A is used as the transmission technology. Corresponding bus connections must be
provided at the individual bus stations or nodes for fail-safe functioning of the PROFIBUS.
LED signals
The following five status LEDs are available on the PROFIBUS module:
LED
Color
Description
H1
Green
Relay K1 picked up
LED H1 switches on when the controller has detected the
CLOSED position and the pulse generator ceases to output
pulses. The LED H1 is controlled by the basic module (signal
X200.11).
H2
Green
Relay K2 picked up
LED H2 switches on when the current distance of the door to
the OPEN position falls below 2 cm and the relay has switch‐
ed on. The LED H2 is controlled by the basic module (signal
X200.9).
H3
Green
Valid incoming telegram
LED H3 is controlled by the basic module (signal X200.12),
and indicates the communication status. The LED flashes to
indicate incoming, valid telegrams. Each signal change
stands for such a telegram.
H400
Red
"Bus error" PROFIBUS communication disrupted
The H400 LED flashes red in the event of PROFIBUS commu‐
nication errors.
H401
Red
"Group error" internal communication disrupted
The H401 LED flashes red in the event of internal communi‐
cation errors. Extended PROFIBUS diagnostic data is being
transferred
H402
Green
Power on
LED H401 lights a continuous green after Power on.
H403
Yellow
Internal communication to main controller
LEDs H403 and H404 toggle each time after the master has
H404
Yellow
sent or received an error-free telegram.
H405
Yellow
Boot
H700
Orange P5V_ISO (X705.6) = OK
H701
Yellow
P5V = OK
140
Position
H400
H700
H405
H403
H404
ATD4xxW for industrial applications
System Manual, 06/2022, A5E51901827B AA
H401 H402
H701
H3
H1
H2