Block positioning control
V
Positioning complete (00)
Address(+)
direction
Address(-)
direction
V
Positioning start signal
OFF
OFF
Start complete signal
OFF
BUSY signal
OFF
Positioning complete
signal
Block positioning is a control that continuously executes the positioning of specified
blocks. One block equivalent to a series of positioning data up to the completion of
positioning (operation pattern = 00) by Independent or continuous positioning control.
A maximum of 50 blocks per axis can be specified.
Using a one-time start command from the PLC CPU or external, complex positioning
control can be performed.
The block positioning control can be performed by specifying the positioning start
number and positioning start information in the buffer memory.
One block
ON
ON
ON
ON
Positioning continue (01)
Positioning
complete (00)
Positioning
continue (11)
One block
1 - 16
Chapter 1 Product Outline
Dwell time
Positioning
complete (00)
Positioning
continue (11)
One block
t