[Da.16] Condition operator
01H : =P1
02H : P1
03H : P1
04H : P1
05H : P1 P2
06H : P1, P2
07H : DEV=ON
08H : DEV=OFF
[Da.16] Condition operator
01H : =P1
02H : P1
03H : P1
04H : P1
05H : P1 P2
06H : P1, P2
07H : DEV=ON
08H : DEV=OFF
[Da.18] Parameter 1
Set the parameters as required for the "[Da.16] Condition operator" and "[Da.23]
Number of simultaneous starting axes".
[Da.23] Number of
simultaneous
starting axes
2 to 4
(positioning data
[Da.19] Parameter 2
Set the parameters as required for the "[Da.16] Condition operator" and "[Da.23]
Number of simultaneous starting axes".
[Da.23] Number of
simultaneous
starting axes
2 to 3
4
(positioning data
Chapter 5 Data Used for Positioning Control
Setting value
The value of P1 should be equal to or smaller than the
value of P2. (P1 P2)
Value
If P1 is greater than P2 (P1>P2), the error "Condition
data error" (error code 533) will occur.
Set the device bit No.
Value
(bit No.)
X: 0H to 1H, 10H to 1FH Y: 0H, 1H, 10H to 1FH
Set the positioning data No. for starting axis set in
"[Da.24] Simultaneous starting axis No.1" and/or
"[Da.25] Simultaneous starting axis No.2".
Value
Low-order 16-bit : Simultaneous starting axis
No.)
High-order 16-bit : Simultaneous starting axis
Setting value
—
Not used. (No need to be set.)
The value of P2 should be equal to or greater than the
value of P1. (P1 P2)
Value
If P1 is greater than P2 (P1>P2), the error "Condition
data error" (error code 533) will occur.
—
Not used. (No need to be set.)
Set the positioning data No. for starting axis set in
"[Da.26] Simultaneous starting axis No.3"
Value
Low-order 16-bit : Simultaneous starting axis
No.)
High-order 16-bit : Not used (Set "0")
5 - 88
Setting details
No.1 positioning data No.1 to
600 (01H to 258H)
No.2 positioning data No.1 to
600 (01H to 258H)
Setting details
No.3 positioning data No. 1 to
600 (01H to 258H)