6-4-7. Storemib Command

This command is used to backup copy of the current MIB settings.
Command format : storemib nnnnn
The serial number is verified with the serial number (nnnnn) entered by user. After that, the MIB settings
are returned to the original settings that have been backed up beforehand.
If the serial numbers do not match, an error is issued and the MIB settings cannot be read.
Execution example
1. Enter "storemib 10001".
The backup copy of the current MIB settings is created.
SNMPCmd>storemib 10001
Success to store

6-4-8. Quit Command

This command is used to quit the SNMP setup mode and to return to the menu of normal operation.
Command format : quit
SNMPCmd>quit
Cmd>