10.2 V-Tool Error
Code
Contents
0x0000 Normal
0x0002 Hardware is abnormal.
(time-out error etc.)
0x0004 Access refusal
(operation mode is
injustice)
0x0101
Command code error
0x0102
Text format error(size)
0x0103
Text parameter error
6F8C1120
Table 10-2 V-Tool error
Normal
Target node has seceded from the network though the command for that
node was received from V-Tool.
FL654 is set to AUTO/CONF specification, the following command was
received from V-Tool.
Writing of Cyclic transmission specification, Message transmission
specification, Token watch time, Minimum permissible frame interval,
Talker area, Node name, I/O module configuration information setting,
I/O data allocation Information setting.
Clear Error counter, Clear Memory, Read out Operation history log,
Error reset command, RUN command, HALT command,
FL654 is set to TOOL specification, FL654 is I/O run mode, the following
command was received from V-Tool.
Writing of Cyclic transmission specification, Message transmission
specification, Token watch time, Minimum permissible frame interval,
Talker area, Node name, I/O module configuration information setting,
I/O data allocation Information setting.
FL654 is set to TOOL specification, FL654 is Down mode, the following
command was received from V-Tool.
Writing of Cyclic transmission specification, Message transmission
specification, Token watch time, Minimum permissible frame interval,
Talker area, Node name, I/O module configuration information setting,
I/O data allocation Information setting.
"command" of the transmission frame received from V-Tool is abnormal.
"Address_data_type" or "Address_data_length" in the transmission frame
received from V-Tool is abnormal.
"MsgLen" in the transmission frame received from V-Tool doesn't agree with
the length of the transmission message of a pertinent command.
"Data_type" or "Data_number" in the transmission frame received from
V-Tool is abnormal.
Network address part of IP address in the transmission frame received from
V-Tool is different from the network address of the node.
I/O initialization abnormality
*I/O configuration is not preserved or it is destroyed.
*I/O configuration and actual I/O mounting information are different.
*I/O that can not support is mounted.
*Cyclic area allocation of I/O configration is abnormal.
*The head address of talker is not a range of 0 to 8703.
Module parameter abnormality
Cyclic area of I/O configuration beyond the limits of own cyclic taker area.
Token watch time beyond the limits of 1to 255
Minimum permissible frame interval beyond the limits of 0 to 50