2-2. DIAG Memu
LCD Display (factory setting)
DIAG 6-3
VTR MODE SEL-3
63 00000
1 2 3 4 5
DIAG 6-4
VTR MODE SEL-4
64 00
1 2
DIAG 6-5
VTR MODE SEL-5
65 000
1 2 3
2-32
Description
1. TC OUT : Sets the time code output.
0 : Outputs PB/TCG.
1 : Outputs TCG.
2. EXT-LK UBIT : Sets the LTC UB set value when the time code is locked externally.
0 : Internally set value
1 : External LTC value
3. EXT-LK DF/NDF : Sets the DF/NDF (NTSC only).
0 : Conforms to the DF/NDF switch setting on the inside panel.
1 : Conforms to the external LTC setting.
4. WATCH AUTO ADJ : Sets the internal timer automatic time correction (according to the
user's bit of the unit connected to TC OUT).
0 : Corrects.
1 : Not correct.
5. UB WATCH MIX : Sets whether to output the time of an internal timer to the LTC UB.
0 : Not output.
1 : Outputs.
1. REC TALLY BLINK : Sets whether the TALLY lamp blinks during battery before end
and tape before end.
0 : Blinks.
1 : Lights.
2. LIGHT OFF NEAR END : Sets whether to turn off the light during battery before end.
0 : Turns off forcibly.
1 : Not turn off.
1. REC START/STOP TONE : Sets whether to output a sound when the REC START/
0 : Outputs no sound.
1 : Outputs a sound.
2. SHOT NO. RESET : Sets whether to reset the shot number automatically during tape-
threading.
0 : Resets automatically.
1 : Not reset.
3. SHOT TIME DISP : Sets the format of the time displayed on the LCD.
0 : Month Day : Hour Minute
1 : Day Month : Hour Minute
2 : Day : Hour Minute Second