Technical Data; Front Panel And Enclosure; Touchscreen And Display - Bosch Rexroth IndraControl VCP 11.2 Project Planning Manual

The small operator terminal vcp 11 is a machine operator terminal which can initiate functions in the machine as defined in the application
Table of Contents

Advertisement

R911311481 / 03 | Rexroth IndraControl VCP 11.2

Technical Data

4
Technical Data
4.1

Front Panel and Enclosure

Front Panel and Enclosure
Enclosure
Front Panel
Seal
Mounting Cutout
Mounting Depth
Degrees of Protection
Total Weight
4.2

Touchscreen and Display

Touchscreen
Type
Activation Force
Durability
Display
Type
Resolution (pixels)
Colors
Reading angle
Electric Drives and Controls | Bosch Rexroth AG
VCP 11.2
Steel Sheet, Galvanized
Aluminum, anodized natural finish
96 mm x 130 mm x 5 mm (3.78" x 5.118" x 0.196") -
(H x W x D)
Circumferential Rubber Seal on the Rear
88 mm x 122 mm (3.465" x 4.803") - (H x W)
Standard: About 33 mm
(1.299")
Fieldbus: About 45 mm
(1.772")
Front: IP65
Rear: IP20
About 500 g
Analog Resistive, 4-Wire Technology
15 g (Standard)
With R8 HS60 Silicon Rubber
No Damages or Malfunctions after 3 Million Strokes un-
der the following conditions:
Stroke Element: R8, HS40 Silicon Rubber
Stroke Force: 150 g
Stroke Frequency: 3 Hz
VCP 11.2
FSTN (mono)
320 x 240
5 Shades of gray
80°
VCP 11.2T
Standard: About 34 mm
(1.339")
Fieldbus: About 46 mm
(1.811")
VCP 11.2T
TFT (color)
320 x 240
256
140°
4-1