Power supply to external units (X5, output)

Connection:
to X5; STKK, grid 3.5 mm, 2- or 6-pole,
max. 1.5 mm
Mating connectors are comprised in the
delivery.
Cable length:
subject to the circuitry connected to X4. Refer to
description below.
Cable type:
unshielded, VDE 0281, 0812 (e.g.: Ölflex)
For 24 V
power supply to external devices.
DC
Timer
X4
10
int. logic
11
X5
max.
0.5 A
1
2

Fig. 75: Power supply to external consumers

The maximum current-carrying capacity/cable length connected to X5
is subject to the voltage source used and the total cable length between
the source and the external consumer. However, the max. current load
on X5 must not exceed 0.5 A.
Please make sure that the maximum current load (source, connec­
"
tions) and cable lengths specified are not exceeded!
The voltage source to be used for supplying X5 is defined by the
other circuitry connected to X4.
The unit's internal power generation (refer to page 366) as well as an
external power supply unit can be used here. For this purpose, only a
few jumpers have to be inserted/removed at X4.
For more information concerning the connections to X4, please refer
to Sect. 7.2.9 starting on page 368.
Bosch Rexroth AG
2
.
Power infeed for supply to
24 V
DC
- internal control logic and
0 V
- X5
external
consumer
24 V
0 V