Power Supply X4; External Device X5; Stop Circuit; Synchronization Voltage (Only With Pst) - Bosch PST 6101.321 Technical Information

Timer and i/o level
Table of Contents

Advertisement

Electrical connection
7.1.4

Power supply X4

7.1.5

External device X5

7.1.6

Stop circuit

7.1.7

Synchronization voltage (only with PST)

7-6
PST 6101.321 / PSI 6101.321
see section 7.2
+24 V DC are output at interface X5 for supplying an external unit (maximally 2A, depend-
ing on the external supply).
A fault in the stop circuit is automatically acknowledged when corrected.
A fault in the synchronization voltage is automatically acknowledged when corrected.