PSI 6xxx
5.2.4.16

"ComnetM-DP" (PROFIBUS-DP) I/O module

Voltage supply
Discrete signal outputs and inputs
PROFIBUS connection
Features:
• 16 discrete inputs (24 V
• 16 discrete outputs (24 V
• PROFIBUS-DP connection via bus copper cable
Function:
• Linking the timer's I/Os to the higher-level PLC or the robot
• via PROFIBUS-DP and a copper cable (serial I/Os) and
• via discrete 24 V signals at X11...X14 (parallel I/Os).
Table 16:
Technical data: "ComnetM-DP" I/O module
Operating voltage
Power input
Power loss
Signal inputs
Signal outputs
Connection:
X10: 4-pole;
STKK, grid 3.5 mm, max. 1.5 mm
Mating connector is comprised in the delivery.
Cable length:
(from power source to consumer)
max. 10 m at 0.75 mm
max. 75 m at 1.5 mm
Cable type:
unshielded, VDE 0281, 0812 (e.g.: Ölflex)
Connection:
X11...X14: 8-pole;
STKK, grid 3.5 mm, max. 1.5 mm
Mating connector is comprised in the delivery.
Cable length:
max. 100 m at 0.5 mm
Cable type:
unshielded, VDE 0281, 0812 (e.g.: Ölflex)
Connection:
X15
Cable length:
according to PROFIBUS-DP specification
Cable type:
copper cable, according to PROFIBUS-DP
specification
PROFIBUS address: Setting via "DP-ADR" switches.
Bosch Rexroth AG
Information on this product
)
DC
)
DC
+24 V= ; +20 %, -15 %
with max. +/-5 % ripple
max. 2 A
subject to circuitry connected to the signal inputs/
outputs
0.5 VA per active input
2.4 VA per active output
logic 1: +16 V ... +30 V, 20 mA
logic 0: -1 V ... +4 V
+24 V, max. 0.1 A, short-circuit-proof
2
2
2